Hp Smart Array P410 Raid Controller Driver: Full Version Software
HP ProLiant Smart Array SAS/SATA Controller Driver for Windows Server 2012 By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Interesting issue. So the HP RAID controller driver from around 2001 to ~2009 was the CCISS driver. There was a transition to the HPSA driver at some point, moving the Smart Array controller support back into the regular SCSI subsystem versus the dedicated block driver. Canon Paperport Scanner Software more.
Hello, I need this tool compiled for FreeBSD 8.0-STABLE (amd64). How To Install Apache With Php On Linux. Currently the ports distribution is marked as broken for amd64, and trying to install gives this message: '===>hpacucli-7.50_3 is marked as broken: currently does not work on amd64 (see ports/128288).
*** Error code 1 Stop in /usr/ports/sysutils/hpacucli.' I am trying to diagnose an issue with my Smart Array P410 rebuilding the RAID 1+0 array using the hot-spare once or twice a week. I've installed /usr/ports/sysutils/smartmontools hoping it would provide some useful data. Hp Color Laserjet 4550 Printer User Manual there. @Alzhy, I can't afford the downtime! This system is a back-office system in production for a CFTC regulated Commodities Exchange. I wrote a simple shell script to run cciss_vol_status once a day, and email me when the array status returns UNHEALTHY.
The problem with this is that by the time I arrive to the office in the morning, receive the UNHEALTHY alert email, and finally make my way to the server room; the array finished rebuilding and all LED indicators show good status. I have twice checked in on it remotely during the night session when the script returned UNHEALTHY, and cciss_vol_status does say that the array is rebuilding using the hot-spare. Though, when I get in to the office in the morning to physically check the machine, the array status is HEALTHY with the hot-spare returned to available status. I've received two alerts from HP regarding the Smart Array P410i controller: and However I have been unable to ascertain from the notes whether these updates pertain to my issue. As such, with these servers in production, I have neglected to research patch methods under FreeBSD (I suspect I will have to create a LiveCD running Windows or Linux, since UNIX and UNIX-like support seems to be restricted to HPUX). Thanks for the response! I should mention that HP has already replaced two failed SAS drives from this particular server.